In order to give you a better service Pepperl+Fuchs uses cookies. By continuing to browse the site you are agreeing to our use of cookiesI agree.
Serviceline
Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537

Multiple-Beam Light Barriers


Narrow down search result list

Product Selector Tool Results: 258 Product(s)

Resolution

Number of Beams

Protection Field Height

Max. Detection Range

Operating Mode

Safety Output

Connection Type

Safety Type

Safety Integrity Level

Performance Level


Choose your product


Next PageLast Page
Product
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Slim design, mounting on three sides, Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m
, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mm
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 60 mm , Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 90 mm, Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mm
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 60 mm , Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 90 mm, Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light grids
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light grids
Next PageLast Page