Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537
Not available for purchase
Not available for purchase

NAMUR Resistor Network F-NR-Ex1

F-NR-Ex1
  • 1-channel
  • Dry contact input
  • For line fault detection (LFD)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  F-NR-Ex1

Supply
Rated voltagemax. 20 V DC
Electrical specifications
Resistor1 kΩ/0.6 W
10 kΩ/0.6 W
Input
Error detectionlead breakage, short circuit, open switch, closed switch
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals , Wire cross section: ≤1.5 mm2
Cable0.75 mm2 x 150 mm
Massapprox. 20 g
Dimensions∅15.5 x 35 mm (0.61 x 1.38 inch)
Length150 mm
Diameter15.5 mm
Data for application in connection with hazardous areas
Certificate
Temperature classT5
Voltage20 V
Power0.6 W
Ambient temperature60 °C (140 °F)
Internal capacitance0 F
Internal inductance0 H
General information
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027260118
ECLASS 12.027024401
ECLASS 11.027024401
ECLASS 10.0.127024401
ECLASS 9.027024401
ECLASS 8.027024401
ECLASS 5.127279290
ETIM 9.0EC002303
ETIM 8.0EC002303
ETIM 7.0EC002303
ETIM 6.0EC002303
ETIM 5.0EC003015
UNSPSC 12.132121610

Details: F-NR-Ex1

Product Documentation: F-NR-Ex1

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction Manual F-NR*-Ex1 / Betriebsanleitung F-NR*-Ex1ALLPDF69 KB
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.