Product

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Current or voltage output, Factory configured input/output, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508

2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508