In order to give you a better service Pepperl+Fuchs uses cookies. By continuing to browse the site you are agreeing to our use of cookiesI agree.
Serviceline
Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537

Signal Converters


Narrow down search result list

Product Selector Tool Results: 18 Product(s)

Input

Output

Power Supply

Special


Choose your product


Next PageLast Page
Product

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Input: Temperature, Rated voltage: 19 ... 30 V DC, Output: 4-20 mApa

1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD), Input: Current/voltage, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mApa

1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection, Input: Resistance, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mApa

1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mApa

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-10 V, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-5 V, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 0-20 mA, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508, Input: Resistance, Rated voltage: 20 ... 35 V DC, Output: 4-20 mA, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mApa
Next PageLast Page
Download the compendium on Functional Safety

Free PDF Download: Compendium Functional Safety

Download our free PDF compendium on Functional Safety and learn more about the specific standards and methods of risk reduction. We also show you how to implement safety equipment and provide you with a helpful glossary for your daily work.