Serviceline Industrial Sensors
Serviceline Explosion Protection

Passive Isolator S1SL-1AI-1C

S1SL-1AI-1C
  • 1-channel signal conditioner
  • Field side loop powered
  • Current input/output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Connection via screw terminals

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  S1SL-1AI-1C

General specifications
Signal typeAnalog input
Operation timeMTBF: 2865 a acc. to SN 29500
stationary continuous operating, average ambient temperature 40 °C (104 °F)
Supply
Rated voltage2.2 ... 30 V DC , loop powered
Power dissipation0.05 W
Power consumption0.3 W
Input
Connection sidefield side
Connectionterminals 5+, 6-
Input signal0/4 ... 20 mA , max. 50 mA
Input voltage≥ 2.3 V + I x load , max. 30 V
Voltage drop≤ 2.3 V
Output
Connection sidecontrol side
Connectionterminals 3-, 4+
Analog current output0/4 ... 20 mA, load ≤ 600 Ω
Ripple≤ 10 mV eff
Transfer characteristics
Accuracymax. 0.1 % of full-scale value
Deviation
Influence of load0.05 % of the measured value per 100 Ω
Influence of ambient temperature< 100 ppm/K of full-scale value
Frequency range0 ... 100 Hz
Rise time/fall time≤ 3.5 ms
Galvanic isolation
Field circuit/control circuitsafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Indicators/settings
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Degree of protectionIEC 60529:2001
Protection against electrical shockEN 61010-1:2010
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Core cross section0.5 ... 2.5 mm2 (20 ... 14 AWG)
Massapprox. 70 g
Dimensions6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height97 mm
Width6.2 mm
Depth107 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
CertificateDEMKO 16 ATEX 1750X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
UL approvalE106378
IECEx approval
IECEx certificateIECEx UL 16.0116X
IECEx markingEx nA IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210129
ECLASS 12.027210129
ECLASS 11.027210129
ECLASS 10.0.127210129
ECLASS 9.027210129
ECLASS 8.027210190
ECLASS 5.127210107
ETIM 9.0EC002919
ETIM 8.0EC002919
ETIM 7.0EC002919
ETIM 6.0EC002919
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: S1SL-1AI-1C

This signal conditioner provides the galvanic isolation between field circuits and control circuits.

The device transfers a 0/4 mA ... 20 mA signal of a current source from the field side to the control side.

This device is loop powered. No additional power supply has to be connected.

Datasheet: S1SL-1AI-1C

DatasheetFile TypeFile Size
Datasheet S1SL-1AI-1CPDF755 KB
Fiche de données S1SL-1AI-1CPDF758 KB
Datenblatt S1SL-1AI-1CPDF756 KB
Datasheet S1SL-1AI-1CPDF761 KB
Hoja de datos S1SL-1AI-1CPDF757 KB

Documents: S1SL-1AI-1C

Instruction manualsFile TypeFile Size
Návod k poużitíPDF132 KB
Instruktions manualPDF0 KB
Instruction manualPDF136 KB
KasutusjuhendPDF127 KB
KäyttöohjePDF127 KB
Manuel d'instructionsPDF138 KB
BetriebsanleitungPDF137 KB
Οδηγίες χρήσηςPDF141 KB
HandleidingPDF0 KB
Instruction manual / BetriebsanleitungPDF130 KB
Manuale di istruzioniPDF135 KB
Lietošanas pamācībaPDF131 KB
Instrukciju vadovasPDF0 KB
Instrukcja obsługiPDF134 KB
Manual de instruçõesPDF132 KB
Manual de utilizarePDF0 KB
Návod na poużitiePDF131 KB
Navodila za uporaboPDF130 KB
Manual de instruccionesPDF137 KB
ManualPDF129 KB
Tender Texts
Tender textD815 KB
AusschreibungstextD815 KB
Application reports
Application Report - Sand Trap and Preliminary Sedimentation StagePDF448 KB
Applikationsbericht - Sandfang und VorklärungPDF434 KB
Documents
System ManualPDF2706 KB
SystemhandbuchPDF2715 KB

Approvals+Certificates: S1SL-1AI-1C

CertificatesFile TypeFile Size
Canada UL cULLINK---
Europe DEMKO ATEX Category 3 GPDF1876 KB
UL Non-Sparking nA IECEx Certificate of ConformityLINK---
USA ULLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF468 KB

Associated Products: S1SL-1AI-1C

Matching System Components
Interface for Power Bus, Supply current 3 A, LED status indication, Connection via screw terminalspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa